Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Ital J Dermatol Venerol ; 159(2): 83-104, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38650492

RESUMO

Allergic contact dermatitis (ACD) is a common inflammatory skin disease caused by delayed hypersensitivity to chemical and biotic contact allergens. ACD significantly affects the patients' quality of life negatively impacting both occupational and non-occupational settings. Patch testing is the gold standard diagnostic in vivo test to precise the ACD etiology and to correctly perform prevention. According to the Italian Medicines Agency (AIFA) legislative decree no. 178 of 29th May 1991, allergens are defined as medicines and therefore they are subject to strict regulation. In 2017, AIFA (decree no. 2130/2017) started a procedure to regulate contact allergens on the Italian market and actually the contact allergens temporarily authorized are reported in AIFA decree no. 98/2022, valid until November 2023. The availability on the market of contact allergens to diagnose ACD and continuous updating on the basis of new epidemiological trends are mandatory, jointly with the continuous update of the baseline and integrative series for patch testing. For this reason, the scientific community represented in Italy by the Skin Allergies Study Group of SIDeMaST (Italian Society of Dermatology and Venereology) and SIDAPA (Italian Society of Allergological, Occupational and Environmental Dermatology) are constantly working, in close relationship with the European scientific communities with large expertise in this important sector of the modern Dermatology. Herein, we report the setting up of regulatory legislation by AIFA and the new Italian Adult Baseline Series for patch testing.


Assuntos
Alérgenos , Dermatite Alérgica de Contato , Testes do Emplastro , Itália , Testes do Emplastro/métodos , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/imunologia
2.
Contact Dermatitis ; 90(5): 479-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38268123

RESUMO

BACKGROUND: Eyelid dermatitis is a frequent reason of dermatological consultation. Its aetiology is not univocal, being contact dermatitis, both allergic and irritant, the most frequent. The primary sources of allergen exposure include cosmetics, metals, and topical medications, from direct, indirect, or airborne contact. OBJECTIVES: To define the frequency of positive patch test reactions to SIDAPA baseline series allergens, to document positive allergens, and to precise the final diagnosis in patients with eyelid involvement. METHODS: A total of 8557 consecutive patients from 12 Italian Dermatology Clinics underwent patch testing with SIDAPA baseline series in 2018 and 2019. Patients were divided into two groups: (i) with eyelid involvement with or without other involved sites (E-Group) and (ii) without eyelid involvement (NE-Group). The final diagnosis and the frequency of positive relevant patch test reactions were evaluated. RESULTS: E-Group consisted of 688 patients (females 78.6%, mean age 45.3 years), 8.0% of 8557 consecutively patch-tested patients. The final diagnosis in E-Group was ADC in 42.4%, ICD in 34.2%, and AD in 30.5%. The highest reaction rates were elicited by nickel sulphate and methylchloroisothiazolinone/methylisothiazolinone in both E-Group and NE-Group, even if these allergens were significantly more frequently positive in NE-Group patients than in E-Group ones. Positive patch test reactions to fragrance Mix II, dimethylaminopropylamine, and sorbitan sesquiolate were significantly more frequent in E-Group patients than in NE-Group ones. CONCLUSIONS: Eyelid dermatitis is a frequent dermatological complaint. Allergic contact dermatitis is the most frequent diagnosis commonly caused by nickel sulphate, isothiazolinones, and fragrances. The surfactants dimethylaminopropylamine and sorbitan sesquioleate are emerging causes of eyelid allergic contact dermatitis.


Assuntos
Blefarite , Dermatite Alérgica de Contato , Níquel , Feminino , Humanos , Pessoa de Meia-Idade , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Testes do Emplastro/efeitos adversos , Pálpebras , Itália/epidemiologia , Estudos Retrospectivos
3.
Artigo em Inglês | MEDLINE | ID: mdl-38284131

RESUMO

BACKGROUND: There is limited epidemiological evidence on outcomes associated with dupilumab exposure during pregnancy; monitoring pregnancy outcomes in large populations is required. OBJECTIVE: To investigate the potential association between exposure to dupilumab in pregnant women with atopic dermatitis and any adverse pregnancy, neonatal, congenital and post-partum outcomes. METHODS: We performed a multicentre retrospective cohort study across 19 Italian tertiary referral hospital. Childbearing women were eligible if aged 18-49 years and carried out the pregnancy between 1 October 2018 and 1 September 2022. RESULTS: We retrospectively screened records of 5062 patients receiving dupilumab regardless of age and gender, identifying 951 female atopic dermatitis patients of childbearing age, 29 of whom had been exposed to the drug during pregnancy (3%). The median duration of dupilumab treatment prior to conception was 22.5 weeks (range: 3-118). The median time of exposure to the drug during pregnancy was 6 weeks (range: 2-24). All the documented pregnancies were unplanned, and the drug was discontinued in all cases once pregnancy status was reported. The comparison of the study cohort and the control group found no significant drug-associated risk for adverse pregnancy, congenital, neonatal or post-partum outcomes. The absence of a statistically significant effect of exposure on the event was confirmed by bivariate analysis and multivariate analysis adjusted for other confounding factors. CONCLUSIONS: This cohort of pregnant patients exposed to dupilumab adds to the existing evidence concerning the safety of biologic agents in pregnancy. No safety issues were identified regarding the primary outcome assessed. In clinical practice, these data provide reassurance in case of dupilumab exposure during the first trimester. However, the continuous use of dupilumab throughout pregnancy warrants further research.

7.
JAMA Dermatol ; 159(3): 267-274, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36652228

RESUMO

Importance: The common use of isothiazolinones as preservatives is a global cause of allergic contact dermatitis. Differences in allowable concentrations of methylisothiazolinone (MI) exist in Europe, Canada, and the US. Objective: To compare the prevalence of positive patch test reactions to the methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) combination and MI alone in North America and Europe from 2009 to 2018. Design, Setting, and Participants: This retrospective analysis of North American Contact Dermatitis Group, European Surveillance System on Contact Allergies (ESSCA), and the Information Network of Departments of Dermatology (IVDK) databases included data from patients presenting for patch testing at referral patch test clinics in North America and Europe. Exposures: Patch tests to MCI/MI and MI. Main Outcomes and Measures: Prevalence of allergic contact dermatitis to MCI/MI and MI. Results: From 2009 to 2018, participating sites in North America and Europe patch tested a total of 226 161 individuals to MCI/MI and 118 779 to MI. In Europe, positivity to MCI/MI peaked during 2013 and 2014 at 7.6% (ESSCA) and 5.4% (IVDK) before decreasing to 4.4% (ESSCA) and 3.2% (IVDK) during 2017 and 2018. Positive reactions to MI were 5.5% (ESSCA) and 3.4% (IVDK) during 2017 and 2018. In North America, the frequency of positivity to MCI/MI increased steadily through the study period, reaching 10.8% for MCI/MI during 2017 and 2018. Positive reactions to MI were 15.0% during 2017 and 2018. Conclusions and Relevance: The study results suggest that in contrast to the continued increase in North America, isothiazolinone allergy is decreasing in Europe. This trend may coincide with earlier and more stringent government regulation of MI in Europe.


Assuntos
Dermatite Alérgica de Contato , Humanos , Prevalência , Estudos Retrospectivos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , América do Norte/epidemiologia , Europa (Continente)/epidemiologia , Testes do Emplastro/métodos
12.
Contact Dermatitis ; 86(5): 379-389, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35099073

RESUMO

BACKGROUND: In 2019, a number of allergens (haptens), henceforth, "the audit allergens," were considered as potential additions to the European Baseline Series (EBS), namely, sodium metabisulfite, 2-bromo-2-nitropropane-1,3-diol, diazolidinyl urea, imidazolidinyl urea, Compositae mix II (2.5% or 5% pet), linalool hydroperoxides (lin-OOH), limonene hydroperoxides (lim-OOH), benzisothiazolinone (BIT), octylisothiazolinone (OIT), decyl glucoside, and lauryl glucoside; Evernia furfuracea (tree moss), was additionally tested by some departments as well. OBJECTIVES: To collect further data on patch test reactivity and clinical relevance of the audit allergens in consecutive patients across Europe. METHODS: Patch test data covering the audit allergens in 2019 and 2020 were collected by those departments of the European Surveillance System on Contact Allergies testing these, as well as further collaborators from the EBS working group of the European Society of Contact Dermatitis (ESCD), and the Spanish Grupo Español de Investigación en Dermatitis de Contacto y Alergia Cutánea. As patch test outcome, reactions between day (D) 3 and D5 were considered. RESULTS: Altogether n = 12 403 patients were tested with any of the audit allergen. Positive reactions were most common to lin-OOH 1% pet. (8.74% [95%CI: 8.14-9.37%]), followed by lin-OOH 0.5% pet., and lim-OOH 0.3% pet (5.41% [95% CI: 4.95-5.89%]). Beyond these terpene hydroperoxides, BIT 0.1% pet. was the second most common allergen with 4.72% (95% CI: 4.2-5.28%), followed by sodium metabisulfite 1% pet. (3.75% [95%CI: 3.32-4.23%]) and Compositae mix 5% pet. (2.31% [95% CI: 1.84-2.87%]). For some allergens, clinical relevance was frequently difficult to ascertain. CONCLUSIONS: Despite many positive patch test reactions, it remains controversial whether lin- and lim-OOH should be tested routinely, while at least the two preservatives BIT and sodium metabisulfite appear suitable. The present results are a basis for further discussion and ultimately decision on their implementation into routine testing among the ESCD members.


Assuntos
Alérgenos , Dermatite Alérgica de Contato , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Humanos , Peróxido de Hidrogênio , Limoneno , Testes do Emplastro/métodos , Terpenos
15.
Clin Mol Allergy ; 19(1): 26, 2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34930291

RESUMO

Allergic and immunologic skin diseases negatively impact the quality of life (QoL) of affected patients with detrimental consequences. Nonetheless, in everyday clinical practice the evaluation of QoL is often overlooked. Considering the increasing prevalence of atopic dermatitis, allergic contact dermatitis, hereditary angioedema, cutaneous mastocytosis, and urticaria, it is essential to determine the effects of allergic and immunologic skin diseases on QoL. A joint meeting (GET TOGETHER 2021) of the Italian Society of Allergology, Asthma and Clinical Immunology (SIAAIC) and the Italian Society of Allergological, Occupational and Environmental Dermatology (SIDAPA) aimed to summarize the features of the main QoL tools used in these diseases and to describe the extent of QoL impairment as well as the impact of treatments on QoL, particularly biologic therapies. The assessment of QoL in patients with allergic and immunologic skin diseases relies on generic, organ-specific and disease-specific questionnaires. While generic and organ-specific questionnaires allow comparison between different diseases, disease-specific questionnaires are designed and validated for specific cohorts: the QoL Index for Atopic Dermatitis (QoLIAD) and the Childhood Atopic Dermatitis Impact Scale (CADIS) in atopic dermatitis, the ACD-11 in allergic contact dermatitis, the Angioedema QoL Questionnaire (AE-QoL) and the Hereditary Angioedema QoL questionnaire (HAE-QoL) in hereditary angioedema, the Mastocytosis QoL Questionnaires (MCQoL e MQLQ) in cutaneous mastocytosis, and the Chronic Urticaria QoL questionnaire (CU-Q2oL) in urticaria. Among the many factors that variably contribute to QoL impairment, pruritus can represent the leading cause of patient discomfort. Biologic therapies significantly ameliorate QoL in atopic dermatitis, hereditary angioedema, mastocytosis and chronic urticaria. In general, adequate management strategies are essential for improving QoL in patients with allergic and immunologic skin diseases.

16.
Contact Dermatitis ; 85(3): 317-323, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33931866

RESUMO

BACKGROUND: Budesonide was included in the European Baseline Series in 2000 as the most suitable marker forcorticosteroid hypersensitivity. In the last two decades, a decreasing trend of budesonide allergy has been observed. OBJECTIVES: To estimate the prevalence of positive patch test reactions to budesonide in a large, Italian patch test population, characterizing patients according to MOAHLFA index and evaluating the benefit with extended readings of budesonide patch test. METHODS: Retrospective analysis of patient demographics and patch test results over a 2-year period (2018-2019) was performed at 14 patch test clinics in Italy. RESULTS: Ninety out of 14 544 (0.6%) patients reacted to budesonide 0.01% pet.. Positive reactions were mild in 54.4% and late readings at day 7 showed new positive reactions in 37.8% of patients. The MOAHLFA index showed a significant positive association with male gender, atopic dermatitis, and age >40 years and a significant negative association with hand and face dermatitis. CONCLUSIONS: We documented a low prevalence of budesonide allergy in Italy, confirming its decreasing trend recently reported in the literature. Nevertheless, budesonide needs to be maintained in the baseline series for its good ability to detect corticosteroid sensitization.


Assuntos
Budesonida/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Testes do Emplastro/métodos , Adulto , Distribuição por Idade , Idoso , Budesonida/imunologia , Reações Cruzadas , Dermatite Atópica/diagnóstico , Dermatite Atópica/epidemiologia , Dermatite Ocupacional/diagnóstico , Dermatite Ocupacional/epidemiologia , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Distribuição por Sexo
17.
Contact Dermatitis ; 85(3): 269-273, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33748955

RESUMO

BACKGROUND: Because Myroxylon pereirae (MP), or balsam of Peru, is nowadays almost not used "as such," and fragrance mix 1 (FM1) apparently is more sensitive in detecting fragrance allergy, the usefulness of testing MP in baseline series was recently questioned. OBJECTIVES: Identification of the number of clinically relevant patch test reactions to MP not detected by FM1. METHODS: Retrospective analysis of 12 030 patients patch tested with MP and FM1 for contact dermatitis between January 2018 and December 2019 in 13 Italian dermatology clinics. RESULTS: Four hundred thirty-nine patients (3.6%) had a positive patch test reaction to MP; 437 (3.6%) had a positive patch test reaction to FM1. Positive reactions to both MP and FM1 were observed in 119 subjects (1.0%), 310 (2.6%) reacted to MP only, 304 (2.5%) to FM1 only, 5 to MP and sorbitan sesquioleate (SSO), 9 to FM1 and SSO, and 5 to MP, FM1, and SSO. Single sensitizations were clinically relevant in 75.2% of cases for MP (62.9% current, 12.3% past) and 76.3% for FM1 (70.1% current, 6.2% past). CONCLUSIONS: Based on our results, MP appears to be still worth testing along with FM1 in baseline series, because it allows detection of a remarkable number of fragrance allergies, often relevant, which would be otherwise missed.


Assuntos
Bálsamos/administração & dosagem , Dermatite Alérgica de Contato/diagnóstico , Testes do Emplastro/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bálsamos/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Feminino , Hexoses/administração & dosagem , Hexoses/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Odorantes , Estudos Retrospectivos , Adulto Jovem
18.
Dermatol Ther ; 34(3): e14911, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33619833

RESUMO

Alitretinoin is the only systemic agent approved to treat moderate-severe chronic hand eczema (CHE) unresponsive to potent topical corticosteroids. No nationwide Italian data regarding real-life efficacy, safety, and tolerability of treatment are available. The DECISA project (DErmatology Clinics in Italy: Survey on Alitretinoin) retrospectively examined data from a registry including 15 Dermatology Clinics authorized to prescription of alitretinoin for CHE patients. Disease severity was assessed at baseline, and after 3 and 6 months of treatment, using the 5-point Physician Global Assessment (PGA) and the modified Total Lesion-Symptoms-Severity (mTLSS) scores. Between November 2010 and July 2018, data of 248 male and 190 female patients (mean age 49.71 ± 13.20 years) treated with alitretinoin were collected. Of them, 43.2% had irritant contact dermatitis, 22.2% allergic contact dermatitis, 18.0% atopic dermatitis, 16.7% mixed (irritant/allergic) type of eczema. At 3 months, the 420 re-evaluated patients showed significantly reduced mTLSS and PGA (P < .0000001 vs baseline for both); PGA was clear/almost clear in 35.6% of cases. At 6 months, the 341 re-evaluated patients showed significant (P < .0000001) improvement of mTLSS and PGA vs baseline and 3 months (PGA clear/almost clear: 41.4%). Relapses occurred in 125 patients; 58 underwent an additional course of alitretinoin, with similarly good results. No relevant safety issues were reported; 86 patients experienced adverse effects, which forced 40 to prematurely stop treatment. The DECISA project results confirm the real-life efficacy, safety and tolerability of alitretinoin in the treatment of moderate to severe CHE refractory to standard topical therapies.


Assuntos
Fármacos Dermatológicos , Dermatologia , Eczema , Dermatoses da Mão , Adulto , Alitretinoína , Doença Crônica , Fármacos Dermatológicos/efeitos adversos , Eczema/diagnóstico , Eczema/tratamento farmacológico , Feminino , Dermatoses da Mão/diagnóstico , Dermatoses da Mão/tratamento farmacológico , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Tretinoína/efeitos adversos
19.
Contact Dermatitis ; 84(2): 95-102, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32876992

RESUMO

BACKGROUND: Studies suggest that patch testing with formaldehyde releasers (FRs) gives significant additional information to formaldehyde 1% aq. and should be considered for addition to the European baseline series (EBS). It is not known if this is also true for formaldehyde 2% aq. OBJECTIVES: To determine the frequency of sensitization to formaldehyde 2% aq. and co-reactivity with FRs. To establish whether there is justification for including FRs in the EBS. MATERIALS AND METHODS: A 4-year, multi-center retrospective analysis of patients with positive patch test reactions to formaldehyde 2% aq. and five FRs. RESULTS: A maximum of 15 067 patients were tested to formaldehyde 2% aq. and at least one FR. The percentage of isolated reactions to FR, without co-reactivity to, formaldehyde 2% aq. for each FR were: 46.8% for quarternium-15 1% pet.; 67.4% imidazolidinyl urea 2% pet.; 64% diazolidinyl urea 2% pet.; 83.3% 1,3-dimethylol-5, 5-dimethyl hydantoin (DMDM) hydantoin 2% pet. and 96.3% 2-bromo-2-nitropropane-1,3-diol 0.5% pet. This demonstrates that co-reactivity varies between FRs and formaldehyde, from being virtually non-existent in 2-bromo-2-nitropropane-1,3-diol 0.5% pet. (Cohen's kappa: 0, 95% confidence interval [CI] -0.02 to 0.02)], to only weak concordance for quaternium-15 [Cohen's kappa: 0.22, 95%CI 0.16 to 0.28)], where Cohen's kappa value of 1 would indicate full concordance. CONCLUSIONS: Formaldehyde 2% aq. is an inadequate screen for contact allergy to the formaldehyde releasers, which should be considered for inclusion in any series dependant on the frequency of reactions to and relevance of each individual allergen.


Assuntos
Dermatite Alérgica de Contato/diagnóstico , Formaldeído/administração & dosagem , Formaldeído/efeitos adversos , Testes do Emplastro/métodos , Alérgenos/administração & dosagem , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Humanos , Nitroparafinas/administração & dosagem , Nitroparafinas/efeitos adversos , Propano/administração & dosagem , Propano/efeitos adversos , Propano/análogos & derivados , Ureia/administração & dosagem , Ureia/efeitos adversos , Ureia/análogos & derivados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA